C51/100
CENTRAL HAMPSHIRE PSD — Water Quality Report 2026
Serving 2,274 people · West Virginia
Water Source
Purchased Surface Water
County
—
System ID
WV3301411
Violations
34
Contaminant Test Results
1 contaminant above EPA health goals
| Contaminant | Detected | Limit (MCL) | Status |
|---|---|---|---|
Lead (90th percentile) | 0.003 mg/L | 0.015 mg/L | Above Goal |
EPA Violation History
6
Violations (last 5yr)
3
Unresolved
0
Health-Related
TIER 3Unresolved
Surface water treatment technique failure
TIER 3Unresolved
Surface water treatment technique failure
TIER 3Unresolved
Surface water treatment technique failure
TIER 3Resolved
Failed Level 2 Assessment under Revised Total Coliform Rule
This is a paperwork/process violation — it does not mean a contaminant was detected at unsafe levels.
When: September 1, 2021 – November 30, 2021Rule: Stage 2 DBPREnforcement: Resolving — corrective action underway
TIER 3Resolved
Failed Level 2 Assessment under Revised Total Coliform Rule
This is a paperwork/process violation — it does not mean a contaminant was detected at unsafe levels.
When: September 1, 2021 – November 30, 2021Rule: Stage 2 DBPREnforcement: Resolving — corrective action underway
TIER 3Resolved
Disinfection byproduct treatment technique failure
When: July 16, 2021 – October 16, 2023Rule: Ground Water RuleEnforcement: Resolving — corrective action underway
Understanding violation severity
Tier 1Urgent health risk. Utility must notify all customers within 24 hours.Tier 2Important health or treatment issue. Customers notified within 30 days.Tier 3Administrative or monitoring issue. Reported in the annual water quality report.
Source: EPA Safe Drinking Water Information System (SDWIS) · Updated quarterly
Frequently Asked Questions About CENTRAL HAMPSHIRE PSD
Is CENTRAL HAMPSHIRE PSD water safe to drink?
CENTRAL HAMPSHIRE PSD water receives a grade of C (51/100), which is considered fair. 0 contaminant(s) exceed EPA legal limits and 34 violation(s) are on record. Customers may want to consider using a water filter.
What contaminants has CENTRAL HAMPSHIRE PSD detected?
1 contaminants were tested in CENTRAL HAMPSHIRE PSD's water. Notable contaminants include Lead (90th percentile). No contaminants exceed EPA legal limits. 1 exceed EPA health goals (MCLGs).
Does CENTRAL HAMPSHIRE PSD have any EPA violations?
Yes, CENTRAL HAMPSHIRE PSD has 34 EPA violation(s) on record, with the most recent in 2025. Violation types include Other, MR, TT. 3 are health-based violations.
How many people does CENTRAL HAMPSHIRE PSD serve?
CENTRAL HAMPSHIRE PSD serves approximately 2,274 people, West Virginia. The system provides water to 2 communities: Augusta, Romney.
What type of water does CENTRAL HAMPSHIRE PSD provide?
CENTRAL HAMPSHIRE PSD sources its water from purchased surface water. Surface water comes from rivers, lakes, or reservoirs and typically requires more extensive treatment. The utility's system ID is WV3301411.
How does CENTRAL HAMPSHIRE PSD compare to other utilities in West Virginia?
CENTRAL HAMPSHIRE PSD scores 51/100 with a grade of C (fair). This score indicates room for improvement compared to other utilities. Visit our West Virginia state page for a full comparison of water systems.